3-9
Chapter 3: BIOS setup
Fan Control Mode [Thermal Cruise Mode]
Congurationoptions:[ManualMode][ThermalCruiseMode][SpeedCruise
Mode] [Smart Fan IV Mode]
The following items appear only when you set Fan Control Mode to [Thermal
Cruise Mode].
Target Temperature [50]
Input value range: [0~127]
Tolerance of Temperature [0]
Input value range: [0~7]
Fan Out Start-Up Value [127]
Input value range: [0~255]
Fan Out Stop Value [100]
The Fan Out value decreases to this value if the temperature reaches below
the lowest temperature limit. Input value range: [0~255]
Fan Out Stop Time [60]
Determines the amount of time it takes for the the Fan Out value to fall from
the stop value to zero. Input value range: [0~255]
Critical Temperature [75]
Determines the amount of time Fan Out takes to decrease its value by one
step. Input value range: [0~255]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one
step. Input value range: [0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one
step in intervals of 0.1 seconds. Input value range: [0~255]